Pneumatic marking machine maintenance technology
August 10, 2022
1. The X and Y axis guide rails should be kept clean. Do not allow dust or iron scraps to remain on them, so as not to affect the accuracy of the marking machine guide rails. 2. The X and Y axis guide rails add a little more than 20# oil per month and hold them by hand. Move the marking head back and forth along the X and Y directions for several times; 1. The X and Y axis guide rails should be kept clean and do not allow dust or iron filings to remain on it, so as not to affect the accuracy of the marking machine guide rail;
2.X, Y-axis guide rails add a little more than 20# oil per month, and hold the marking head back and forth in the X and Y directions for several times;
3. Check whether the X and Y axis timing belts are loose on schedule, and check every two months;
4. Keep the marking machine needle cavity clean, do not allow dust, iron filings, etc. to enter the needle cavity, add lubricating oil before use every day (can be injected from the venting hole);
5. When the gas source is connected, the two bodies are drained. At this time, the gas will be discharged, and it will return to normal after a few minutes. Check whether the pneumatic two-link is normal in March;
6. The needle should be refueled regularly. The method of removing the needle is to unscrew the needle sleeve to the left and pull out the rubber seal to pull out the needle and return spring.
7. Oil and iron filings are not allowed on the travel switch;
8. Compressed air should meet the specifications set forth in the technical requirements. Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn