The continuous salt spray test machine is one of the "three preventions" (damp heat, salt spray, and mold) test equipment for artificially simulating the climate environment.
An important salt spray test equipment for various environmental adaptability and reliability in light industry, electronics, light industry electronics, instrumentation and other industries. The salt spray
The testing machine can be used for neutral salt spray test according to GB / T2423.17 "Basic Environmental Test Procedure Test for Electronic and Electrical Products Ka: Salt Spray Test Method", and can also be used for acetate salt spray test.
Built-in functions of continuous salt spray test machine:
The continuous salt spray tester is suitable for surface treatment of various materials, including paint, electroplating, organic and inorganic coatings, anode treatment, anti-rust oil and other anti-corrosion treatments to test the corrosion resistance of its products.
1. Laboratory over-temperature indicator: If there is an over-temperature indicator, it will light up.
2. Laboratory water level indicator: If the laboratory water level is insufficient, this indicator lights.
3. Indicator light at the end of the test: This light is on at the end of the test.
4. Spray indicator: this light is on when spraying.
5. Low water level indicator of the pressure tank: If the water level of the pressure tank is insufficient, this indicator lights.
6. Pressure barrel over-temperature indicator light: this light is on when the pressure barrel is over-temperature.
7. Pressure barrel temperature controller: control the temperature of the pressure barrel, standard temperature setting, brine test 47 ℃, corrosion resistance test method 63 ℃,
Press ▽ to decrease, press △ to increase.
8. Pressure gauge: The pressure indicated by the pointer on this gauge is the pressure reached when the air is heated through the saturated air barrel and the nozzle is delivered.
9. Time counter: cumulative test time.
10. Laboratory temperature controller: control the temperature of the laboratory, standard temperature setting, brine test method 35 ℃, corrosion resistance test method 50 ℃
, Key ▽ is to decrease, key △ is to increase.
11. Timer: The time required for the test can be set arbitrarily, and the automatic shutdown will be completed at the end. (H: hour. M: minute S: second button "+" increases, press button
"-" Is reduced.
12. Power switch: Press this switch to power on the machine and prepare for work.
13. Operation switch: Press this switch to turn on the meter and display related parameters.
14. Spray switch: press this switch for spray test.
15. Timing switch: turn on the timer to start timing.
16. Demisting switch: Press this switch to turn on the mist discharge switch, and the mist in the test chamber is forced to be discharged.
Features: This salt spray test chamber conforms to CNS, ASTM, JIS, ISO standards. The salt spray test is applied to the surface of various materials.
Materials, electroplating, anodizing, anti-rust oil and other anti-corrosion treatment, test the corrosion resistance of its products.
Features of continuous salt spray test machine:
Spray method: A: continuous salt spray test machine B: programmable salt spray test machine.
With full detection system, it can be illuminated when a fault occurs.
· The whole machine is made of imported PVC board, the structure is strong, never deformed, and it is resistant to acid, alkali and high temperature and never aging.
· Adopt automatic / manual water adding system, with the function of automatic / manual water adding when the water level is insufficient, the test is not interrupted, and the water level is insufficient.
Display.
· The mist of the precision glass nozzle diffuses evenly and falls naturally on the test piece to ensure that there is no blocking of crystalline salt.
· The controllers are all on the same board, easy to operate, and clear at a glance.
· With double over-temperature protection, insufficient water level warning to ensure safe use.
· The imported temperature controller has manual and fully automatic control methods, using digital display, PID control, error ± 0.1 ℃, maximum setting
Time can reach 999HrS.
· The laboratory adopts direct steam heating method, the heating speed is fast and uniform, and the standby time is shortened.
· The spray tower is equipped with a cone-shaped diffuser, which has the functions of guiding the mist, adjusting the amount of mist and evenly falling the mist.
· The pressure barrel adopts Henry's law to heat and humidify, and provide the humidity required by the laboratory.
· The upper cover of the test tank of the enlarged model is automatically opened and closed by the pneumatic cylinder, which is easy to operate and has good safety.
· After the test is completed, it has an automatic defogging device, which can clearly observe the test products in the test room.
· Use standard: CNS3627, 3885, 4159, 7669, 8886, JIS D-0201, H-8502, H-8610, K-5400,
Z-2371, ISO 3768, 3769, 3770, ASTM B-117, B-268, GB-T2423, GJB 150.
The above is the relevant technical information of the continuous salt spray test machine.For more equipment information, please visit the Aisili technical consulting website